Setting up and running the device
Mounting, network, connection to Odoo and daily operation.
The Klockix device hangs on the wall and books check-ins and check-outs by badge into Odoo, app Attendances. It also works without a Klockix account. With the Fleet Console a partner manages many devices from one place.

What the device needs
- Power over the network cable (PoE) or a power supply.
- A network with internet access, by cable or Wi-Fi with a password. The device cannot be set up without internet.
- Odoo 17, 18, 19 or 20 with the Attendances app, plus a technical user with an API key or the kiosk link, see Preparing Odoo.
- Badges whose ID is stored with the employees in Odoo (Badge IDs).
- Open ports in the firewall, see Firewall and ports.
Two ways
- Connect to Fleet Console: a registration code is created in the Fleet Console, usually by the partner. The device then fetches configuration, Odoo access and service PIN from the console. Steps under Connecting to the Fleet Console.
- Connect directly to Odoo: Odoo address and access are entered on the device, no Klockix account is needed. The service PIN is set on the device. Steps under Connecting directly to Odoo.
A directly connected device can be linked to the Fleet Console later with a code from the service menu.
Order
- Unboxing and mounting: connect power, choose the language.
- Connecting to the network: cable or Wi-Fi, internet check.
- Choosing the setup path: Fleet Console or directly to Odoo.
- Depending on the path, Connecting to the Fleet Console or Connecting directly to Odoo.
Technical data
| Item | Value |
|---|---|
| Display | 7 inch, 1024 × 600 pixels, touch, landscape |
| Power | PoE over the network cable or power supply |
| Network | Network cable or Wi-Fi, open or with a password (WPA2, WPA3). Not supported: WEP, enterprise Wi-Fi with user sign-in (802.1X) and guest Wi-Fi with a sign-in page. |
| Badge reader | built-in RFID reader |
| Languages on the device | German, English, Spanish, French, Italian and Dutch |
| Odoo | 17, 18, 19 and 20 on Odoo Online, Odoo.sh or your own server |
| Time | synchronised over NTP, shown in 24-hour format in the time zone of the site, on a device connected directly to Odoo in the time zone of Android |
Privacy
Bookings go from the device straight to Odoo. Klockix receives no bookings, no employee names and no badge IDs, not even in a diagnostics package. If a crash report contains a badge ID, the device replaces it with a pseudonym.
What the device stores
- The employee list from Odoo, only when signing in with an API key: Odoo ID, name, department, company, badge ID, time zone, whether the person is checked in and since when. The PIN is stored only as a check value. The device replaces the list with every sync, by default every 10 minutes.
- Bookings: Odoo ID of the person, time and direction, no names. A badge ID only while the device could not assign the booking to a person. The device deletes bookings confirmed by Odoo after 7 days and rejected ones after 30 days.
- A device log of the last 14 days. Bookings appear in it with a pseudonymised badge ID, without names.
- The Odoo access and a check value of the service PIN. Device info, log and diagnostics package never show the access.
With a kiosk link the device stores no employee list and no queue. Every booking goes to Odoo at once and is then kept only in the device log.
What the Fleet Console sees
A device connected to the Fleet Console sends a status report every minute, including versions, state, network type, local IP address, Wi-Fi signal, free storage, time sync, Odoo status as a code, the number of waiting and rejected bookings and the start of the last regular sync of the employee list. On top come technical events such as restart, update and the result of an Odoo test. None of these contain names, badge IDs or individual bookings. At the moment of a booking only the counters change and, if the booking finds an Odoo error, the Odoo status. If Odoo cannot be reached but the Fleet Console can, the number of waiting bookings rises with each booking in the next status report. At a site with only one person, this shows when someone clocked in there.
What the cloud stores, for how long and where is under Privacy in the Fleet Console.
A device connected directly to Odoo sends no status reports. It talks to Klockix only to ask for updates, to check the internet access during setup and for each diagnostics package and, with the diagnostics opt-in, to send crash reports. The update request contains the app and Android version, the device model and a random device identifier.
Diagnostics
A diagnostics package is only created when the Fleet Console requests it and diagnostics are allowed (service menu), or when someone with the service PIN taps “Send diagnostics package now” in the service menu. Below that button the device shows this notice:
The diagnostics package contains technical data of this device: logs of the last 14 days, the configuration without passwords and keys, network information, version numbers and the most recent technical events. It holds no employee names, badge numbers or bookings. Log lines about bookings appear only as a count per day. The package is transferred encrypted to Klockix (stored in Hetzner Object Storage in Germany), kept for 30 days and then deleted automatically. It is used only for troubleshooting by your partner and Klockix.
Badge IDs (“badge numbers” in the notice) are not in the package. Log lines about bookings and touches, the queue, Odoo and opening the PIN prompt of the service menu appear in it only as a count per day, without times or booking IDs. The package also holds the time of the last regular sync of the employee list, the age of the oldest waiting booking in whole quarter hours and the most recent technical events with their times, as the Fleet Console shows them, for example at which quarter hour the queue was reported stuck or when the PIN was locked after failed attempts. At a site with only one person, the daily counts still show on which days someone clocked in there.
A device connected directly to Odoo sends no package. It saves it in the “Download” folder, where a technician collects it over USB. The notice then reads:
The diagnostics package contains technical data of this device: logs of the last 14 days, the configuration without passwords and keys, network information, version numbers and the most recent technical events. It holds no employee names, badge numbers or bookings. Log lines about bookings appear only as a count per day. The device saves the package in the “Download” folder. It leaves the device only when a technician collects it over USB. It is used only for troubleshooting.
The device sends crash reports to Sentry (EU region) only with the diagnostics opt-in, switched on in the Fleet Console or on the device. Before sending, it removes known credentials and replaces badge IDs with pseudonyms. Where the switch is: Service menu.