Foutcodes
De codes die het apparaat toont, met uitleg en de volgende stap.
Toont het apparaat een code, dan staat hier wat die betekent en wat je moet doen. Het apparaat toont zijn teksten in zes talen: Duits, Engels, Spaans, Frans, Italiaans en Nederlands. De tabellen citeren de Engelse versie.

Netwerk
NET-01
| Titel | Tekst | Wat te doen |
|---|---|---|
| No network | The device is not connected to any network. Bookings are stored. | Check the network cable or set up the network again in the service menu. |
NET-02
| Titel | Tekst | Wat te doen |
|---|---|---|
| No Wi-Fi networks found | Move closer to the router or connect a network cable. | Search again. |
NET-03
| Titel | Tekst | Wat te doen |
|---|---|---|
| Connection failed | The Wi-Fi network did not accept the connection. Usually the password is wrong. | Enter the password again or choose another Wi-Fi. |
NET-04
| Titel | Tekst | Wat te doen |
|---|---|---|
| No internet | The network is connected but the internet cannot be reached. The device needs outbound port 443 (HTTPS) and 123 (NTP). | Check again. If it persists, have ports 443 and 123 opened in the firewall. |
NET-05
| Titel | Tekst | Wat te doen |
|---|---|---|
| Browser sign-in required | This Wi-Fi uses a sign-in page. Such networks are not supported. | Choose another Wi-Fi or connect a network cable. |
NET-06
| Titel | Tekst | Wat te doen |
|---|---|---|
| No IP address | The network did not assign an address to the device (DHCP). | Try again. If it persists, ask your network administrator. |
NET-07
| Titel | Tekst | Wat te doen |
|---|---|---|
| Klockix cloud unreachable | Internet works, but the Fleet Console does not respond. "Connect directly to Odoo" is available. | Try again later or have device-api.klockix.com opened on port 443. |
NET-08
| Titel | Tekst | Wat te doen |
|---|---|---|
| Name resolution failed | The network's DNS server does not respond. | Have the network's DNS server checked. |
NET-09
| Titel | Tekst | Wat te doen |
|---|---|---|
| Wi-Fi unavailable | The Wi-Fi module is off or missing. | Use a network cable or contact support. |
NET-10
| Titel | Tekst | Wat te doen |
|---|---|---|
| Network not supported | Enterprise Wi-Fi with user sign-in (802.1X) and WEP are not supported. | Choose another Wi-Fi or connect a network cable. |
Registratiecode
CODE-01
| Titel | Tekst | Wat te doen |
|---|---|---|
| Invalid character | The code has 6 characters without 0, O, 1 and I. | Correct the code. |
CODE-02
| Titel | Tekst | Wat te doen |
|---|---|---|
| Code not valid | The code is unknown, expired (a code is valid for 30 minutes), already used or revoked. Check in the Fleet Console or create a new code. | Enter the code again or create a new one in the Fleet Console. |
CODE-03
| Titel | Tekst | Wat te doen |
|---|---|---|
| Code expired | The code was valid for 30 minutes. Create a new one in the Fleet Console. | Enter the new code within 30 minutes. |
CODE-04
| Titel | Tekst | Wat te doen |
|---|---|---|
| Code already used | Each code is valid for exactly one device. | Create a new code in the Fleet Console. |
CODE-05
| Titel | Tekst | Wat te doen |
|---|---|---|
| Code revoked | The code was withdrawn in the Fleet Console. | Create a new code in the Fleet Console. |
CODE-06
| Titel | Tekst | Wat te doen |
|---|---|---|
| Too many attempts | Try again in … s. | Wait until the lock has expired. |
CODE-07
| Titel | Tekst | Wat te doen |
|---|---|---|
| Fleet Console unreachable | The code could not be checked. Please check the network. | Check the network and try again. |
Odoo
ODOO-10
| Titel | Tekst | Wat te doen |
|---|---|---|
| Invalid address | Enter an address like https://company.odoo.com. | Correct the address. Unencrypted (http) works only with a server on your own network. |
ODOO-11
| Titel | Tekst | Wat te doen |
|---|---|---|
| Address not found | The server name is unknown. Typo? | Check the spelling of the address. |
ODOO-12
| Titel | Tekst | Wat te doen |
|---|---|---|
| Server not responding | No connection to …:…. Firewall or server down? | Have someone check that the server is running and the firewall allows the connection. |
ODOO-13
| Titel | Tekst | Wat te doen |
|---|---|---|
| Invalid certificate | The server certificate has expired or does not match the address. | Have the certificate renewed. On your own server with its own certificate, confirm the fingerprint. |
ODOO-14
| Titel | Tekst | Wat te doen |
|---|---|---|
| Certificate changed | The server presents a different certificate than confirmed. Stopped for safety. | Confirm the new fingerprint in the service menu or in the Fleet Console. |

ODOO-15
| Titel | Tekst | Wat te doen |
|---|---|---|
| No Odoo found | No Odoo server responds at this address. | Check the address: it is the one where Odoo opens in the browser. |
ODOO-16
| Titel | Tekst | Wat te doen |
|---|---|---|
| Version not supported | Found Odoo …. Supported: 17, 18, 19 and 20. | Update Odoo to version 17 or newer. |
ODOO-17
| Titel | Tekst | Wat te doen |
|---|---|---|
| Database not found | Enter the database name under "Advanced". | Ask your IT or your Odoo partner for the name. |
ODOO-18
| Titel | Tekst | Wat te doen |
|---|---|---|
| Proxy asks for sign-in | Password protection (basic auth) sits in front of Odoo. Allow the Odoo address without password protection. | Ask your IT to let the device through without the password, for example by its IP address. |
ODOO-20
| Titel | Tekst | Wat te doen |
|---|---|---|
| Sign-in failed | User or API key is wrong. The key is shown only once when created. | Create a new API key in Odoo and enter it here. |
ODOO-21
| Titel | Tekst | Wat te doen |
|---|---|---|
| API key expiring | The API key expires on …. Create a new one in Odoo and enter it here (or in the console). | Odoo shows the new key only once: copy it and enter it right away. |

ODOO-22
| Titel | Tekst | Wat te doen |
|---|---|---|
| Odoo access invalid | The API key was deleted or has expired. Bookings are stored until access is renewed. | Enter a new API key in the service menu or in the Fleet Console. |

ODOO-23
| Titel | Tekst | Wat te doen |
|---|---|---|
| API blocked on this plan | Odoo Online Standard and One App Free do not allow API access. Please choose "Kiosk link". | Use the kiosk link or move Odoo to the Custom plan. |
ODOO-24
| Titel | Tekst | Wat te doen |
|---|---|---|
| No permission | The user may not read employees. Grant "Employees: Officer" and "Attendances: Administrator" rights in Odoo. | Grant the user the rights named above in Odoo and test again. |
ODOO-25
| Titel | Tekst | Wat te doen |
|---|---|---|
| Attendances not installed | The Odoo app "Attendances" is not installed. | Install the "Attendances" app in Odoo. |
ODOO-26
| Titel | Tekst | Wat te doen |
|---|---|---|
| Booking not allowed | The user may not create attendances. | Allow the user to create attendances in Odoo. |
ODOO-27
| Titel | Tekst | Wat te doen |
|---|---|---|
| Invalid kiosk link | The link looks like: https://company.odoo.com/hr_attendance/abc123… | Copy the link again in Odoo and paste all of it. |
ODOO-28
| Titel | Tekst | Wat te doen |
|---|---|---|
| Kiosk link unknown | Odoo does not know this link. Was it regenerated? | Copy the link again and enter it here. |

ODOO-29
| Titel | Tekst | Wat te doen |
|---|---|---|
| Multiple companies | Choose the company under "Advanced" (or "all"). | If the company is missing from the list, give the user access to it in Odoo. |
ODOO-30
| Titel | Tekst | Wat te doen |
|---|---|---|
| Odoo unreachable | … bookings waiting. | Check the network. The bookings go out as soon as Odoo can be reached. |

ODOO-31
| Titel | Tekst | Wat te doen |
|---|---|---|
| Booking rejected | Odoo rejected a booking (…). Details in the diagnostics package. | HR checks the attendance in Odoo. |
ODOO-32
| Titel | Tekst | Wat te doen |
|---|---|---|
| No badges assigned | No employee in Odoo has a badge ID yet. | Enter the badge ID for the employees in Odoo. |
ODOO-33
| Titel | Tekst | Wat te doen |
|---|---|---|
| Odoo throttling | Odoo is not accepting requests right now. The device retries automatically. | Wait a minute, then test again. |
ODOO-34
| Titel | Tekst | Wat te doen |
|---|---|---|
| Odoo server error | Odoo answered with an error. The device retries automatically. | Try again later. If the error persists, ask your Odoo administrator. |
ODOO-35
| Titel | Tekst | Wat te doen |
|---|---|---|
| Clocking in is currently not possible | Odoo is unreachable right now. With a kiosk link the device cannot book later. Try again in a minute or contact your IT or your partner. | Have the network and the connection to Odoo checked. |

ODOO-36
| Titel | Tekst | Wat te doen |
|---|---|---|
| Clocking in is currently not possible | The device is not fully set up yet: the Odoo connection is missing. Please contact your IT or your partner. | Set up the Odoo connection in the Fleet Console. |

Tijd
CLK-01
| Titel | Tekst | Wat te doen |
|---|---|---|
| Time not synchronised | Booking not possible until the time server confirms the time. | Check the network and wait a minute. |

CLK-02
| Titel | Tekst | Wat te doen |
|---|---|---|
| Time server unreachable | Port 123 (UDP) is probably blocked. | Open port 123 (UDP) in the firewall or set your own time server in the Fleet Console. |
CLK-03
| Titel | Tekst | Wat te doen |
|---|---|---|
| Unknown time zone | "…" is not valid, UTC applies. | Check the site's time zone in the Fleet Console. |
Updates
UPD-01
| Titel | Tekst | Wat te doen |
|---|---|---|
| Update download failed | Will be retried at the next check. | No action needed. |
UPD-02
| Titel | Tekst | Wat te doen |
|---|---|---|
| Update rejected | The update signature is invalid. It was not installed. | Inform Klockix support. |
UPD-03
| Titel | Tekst | Wat te doen |
|---|---|---|
| Installation failed | …. The previous version keeps running. | Inform Klockix support. |
UPD-04
| Titel | Tekst | Wat te doen |
|---|---|---|
| Update rolled back | Version … was not stable, version … is active again. | No action needed. |
UPD-05
| Titel | Tekst | Wat te doen |
|---|---|---|
| Storage low | Updates are loaded again once space is free. | Inform Klockix support. |

UPD-06
| Titel | Tekst | Wat te doen |
|---|---|---|
| No update | Version … is current. | No action needed. |
Fleet Console
FLEET-01
| Titel | Tekst | Wat te doen |
|---|---|---|
| Fleet Console unreachable | Configuration and status will sync later. Bookings are not affected. | No action needed. If it lasts, check the network. |
FLEET-02
| Titel | Tekst | Wat te doen |
|---|---|---|
| Disconnected from the Fleet Console | The device was removed in the console. It keeps booking with the last configuration. | Enter a new registration code in the service menu. |


FLEET-03
| Titel | Tekst | Wat te doen |
|---|---|---|
| Invalid configuration | The new configuration could not be applied; the last valid one stays active. | Inform your partner. |

FLEET-04
| Titel | Tekst | Wat te doen |
|---|---|---|
| Logo not loaded | The Klockix logo is shown. | Check the logo file in the Fleet Console. |
Badgelezer
NFC-01
| Titel | Tekst | Wat te doen |
|---|---|---|
| No badge reader | Neither NFC nor USB reader found. Book via "Choose name". | Contact support. |


NFC-02
| Titel | Tekst | Wat te doen |
|---|---|---|
| NFC switched off | Please contact support. | Contact support and give the status from Service menu › Device info. |

NFC-03
| Titel | Tekst | Wat te doen |
|---|---|---|
| Reader error | The badge reader was restarted. Please tap again. | Hold the badge still until the tone sounds. |
Servicemenu
SVC-01
| Titel | Tekst | Wat te doen |
|---|---|---|
| Wrong PIN | – | Enter the PIN again. |
SVC-02
| Titel | Tekst | Wat te doen |
|---|---|---|
| Locked for … s | – | Wait until the lock has expired. |
SVC-03
| Titel | Tekst | Wat te doen |
|---|---|---|
| PIN too simple | Please choose a different PIN. | Choose another PIN with 4 to 8 digits, not 1234, 2580 or one digit repeated. |
SVC-04
| Titel | Tekst | Wat te doen |
|---|---|---|
| Reset blocked | … bookings are still waiting to be sent. | Connect the device to the network and wait until the bookings are sent. Then reset again. |
SVC-05
| Titel | Tekst | Wat te doen |
|---|---|---|
| Diagnostics not allowed | The diagnostics package was not sent. Neither the Fleet Console nor the device allows sending it. | Allow diagnostics in the Fleet Console, or turn on “Allow sending diagnostics” at the device in the service menu under “Diagnostics”. |
Registraties
BOOK-01
| Titel | Tekst | Wat te doen |
|---|---|---|
| Booking not possible | Odoo is unreachable. With a kiosk link the device cannot book later. | Tap again later. |
BOOK-02
| Titel | Tekst | Wat te doen |
|---|---|---|
| Outside operating hours | Bookings possible from … …. | Book during operating hours. |
BOOK-03
| Titel | Tekst | Wat te doen |
|---|---|---|
| Badge not known | Please contact HR. | Ask HR to assign the badge in Odoo. |
BOOK-04
| Titel | Tekst | Wat te doen |
|---|---|---|
| Already booked at … | – | No action needed. |
BOOK-05
| Titel | Tekst | Wat te doen |
|---|---|---|
| PIN not recognised | Please try again. | Enter the PIN again. |
BOOK-06
| Titel | Tekst | Wat te doen |
|---|---|---|
| Connection interrupted | Check in Odoo whether the booking arrived before tapping again. | If the booking is missing in Odoo, tap again. |